I have removed the panel and checked for burn marks on the back. To help trouble shoot the no power on the display panel. The question is can I take the load out wires and put to L1 post and then put the other to the L2 post to get the main pump running. I followed the wires from the breaker to check for power on far left terminal and where the wire from the breaker is feed to the line in has power. Turning now to signals controlled by the box, the first southbound signal trains. I'm new to all this so I sure I don't have it all correct. Wire up New Pump: You must have 230V to wire a VS pump. Loosen the conduit connector, pull the wires out of the pump and now you can move the old pump out of the way. Hayward control panel replacement- please help my pool is a pond. Shut off the power at the breaker before opening the rear of the motor and removing the 3 wires that come into the pump 2 power lines and a ground wire. However if you prefer a physical control panel at the pump then get the older Intelliflo. Ive attached a few pictures so you can see. Just get them with the I/O board as that only costs about 100 more. It seems like they should just slide out, but I dont want to tug to hard and create another problem for myself. The motherboard inside the control panel needs to be replaced, however, there are a few wires Im struggling to remove. The Pentair is feed through a a seimens 40 amp breaker. I have a Hayward SwimPure Plus control panel for my salt cell system. : Chlorination Default Display Turn power on at the main panel and turn the Pro Logic control power circuit breaker on. Although the Pro Logic is easy to use, it is important to completely read through this operating manual before attempting to operate the control. The first question I have is since cold weather is coming tonight can I bypass the control board and get the Pentair pump running so I can circulate water. The Pro Logic can control pumps, valves, lighting, heaters, and chlorination. I started checking for power and I have power coming from the breaker. I opened up the panel to discover no power to the display. I have a Hayward Goldline Aqua Plus controller to a SWG, Pentair VSP, with a auxillary pump to clean the pool. Controls up to 4 relays, 3 valve actuators, 1 solar and 1 conventional heater. Chlorinator sanitizes pools up to 40,000 gallons. Aqua Plus offers user friendly and cost effective automation. Will be calling the people who installed this on Monday but wondering if there's an easy fix first.Woke up today to find the pool pump not running. It automatically generates its own chlorine using ordinary table salt for pools up to 40,000 gallons. I don't know if that might be the problem? Anyone have advice on what to check or what might be the cause? The only change in the last few days is that it's been raining like crazy. Also, I noticed in the panel with the circuit breakers there's a "cir pump relay". I checked continuity on these 4 thinner wires which is valid so I know it's not a break in the wires between the controller and the pump. These are much thinner wires than the ones powering the pump (above) so assuming the pump itself steps down the voltage to a much lower voltage and am assuming it's still AC power into the control panel. Depending on the model, this button may be labeled reset or labeled with a triangle symbol- either is the reset button. Once the power is off, open the chlorinator unit to expose the controls. The wires are red, black, yellow, green which run from the pump to the control panel. First, turn off the power to the system by unplugging it or switching off the breaker. I was also thinking about checking to see if the voltage is live to the control panel itself but I'm not sure which wires to touch. I tested continuity to the two non ground wires and there doesn't seem to be a break. Which leads should I touch my voltmeter to if I check the power leading into the pump? There's 3 wires, 1 is ground and the other two. Hayward Pro Logic Local Display Keypad GLX-PL-LOC-PS8. Hayward Wireless PS-8 Controller AQL2-TW-RF-PS-8. Hayward CAT 4000 Remote Automated Controller with WiFi Transceiver W3CAT4000WIFI. I haven't checked the voltage into the pump yet but figuring if that has power to the pump then this controller is likely bad. Find many great new & used options and get the best deals for XtremepowerUS 1. Hayward Wireless PS-4 Remote Controller AQL2-TB-RF-PS-4. Checked all wiring and circuit breakers and everything looks good. Noticed today that the controller panel is dark with no display visible and the buttons do nothing. incidence was found in the second year with 45 of rotten fruit compared to 23 in the. Both are about 3-4 years old and have run with no issues. Keywords: Psa, fruit quality, Botrytis rot, Hayward, controlled. Hello All, I have a Jandy pro series variable pump and the Jandy JPE controller.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |